MPC Is NOT a “Condition Measurement”
The article explains that Membrane Patch Colorimetry (MPC) measures the potential for varnish formation in oil rather than existing deposits. Engineers often misinterpret MPC readings, mistakenly thinking low values indicate no varnish problems. MPC serves as a predictive risk indicator, emphasizing the importance of monitoring real-time conditions and correlating them with operational symptoms.